Design Of Sewage Treatment Plants
Design of Sewage Treatment Plants
Presented by: Dr. E.Venkata Rathnam
Usually dispatched in 2 to 3 days
Usually dispatched in 2 to 3 days
Category:
Design Guidelines
Only logged in customers who have purchased this product may leave a review.
Related products
IMS Design Quick Start Guide
The IMSDesign Quick Start Guide contains information about how you can install the Integrated Membrane System Design (IMSDesign) application. Additionally, this guide contains detailed information about setting the options related to different modules of the application.
IMS Design Quick Start Guide
The IMSDesign Quick Start Guide contains information about how you can install the Integrated Membrane System Design (IMSDesign) application. Additionally, this guide contains detailed information about setting the options related to different modules of the application.
Design of Reverse Osmosis Process For The Purification Of River Water In The Southern Belt Of Bangladesh
Introduction
Abundance and quality water supply is essential for all living species. Sustainable agriculture and industrial production need steady supply of freshwater. In many parts of the today’s world, desalination plays a vital role for sustaining human habitation besides the existing conventional water treatment technologies. Membrane based RO process has become a popular method to supply the fresh water from seawater and brackish water in different regions. RO (Figure 1) is a pressure driven process which under pressure reverses the flow direction of the solvent (in the opposite direction of osmosis process). Substantial efforts have been made by researchers on freshwater production (Sassi, 2012) and wastewater treatment (Stoller et al., 2016) using the RO. Rapid growth of membrane desalination processes enhanced the removal of ionic contaminants (Sassi and Mujtaba, 2013), pharmaceutical active compounds (Gur-Reznik et al., 2011) and other types of effluents from chemical, petrochemical, electrochemical, food, paper and tanning industries. Demineralised water can be supplied to several industries by treating the saline water using the RO process. However, there are limited studies on the production of demineralised water. Demineralised water is completely free (or almost) of dissolved minerals (Kremser et al. 2006) which has total dissolved solids (TDS) as low as 1 mg/l. Kremser et al. (2006) described operating experience on demineralized water plant.
In this work, RO based desalination process is considered using three stages described by (Sassi, 2012) as shown in Figure 1. The plant nominal operating and design parameters (of commercial Film Tec spiral wound RO membrane elements) are taken from Abbas (2005). Firstly, the model prediction is validated against those reported by Sassi and Mujtaba (2010). Secondly, an optimization problem incorporating a process model is formulated to optimize the design and operating parameters in order to minimize specific energy consumption and the results are compared with Sassi (2012). Since those models (Sassi, 2012) are validated for freshwater production, the model parameters such as (water and salt permeability coefficients) needs to be updated for demineralised water. A structure of the RO network is developed based on RO network (two-stage seawater pass and two-stage brackish water pass). Different parameters are updated for the model from the literature.
Design of Reverse Osmosis Process For The Purification Of River Water In The Southern Belt Of Bangladesh
Introduction
Abundance and quality water supply is essential for all living species. Sustainable agriculture and industrial production need steady supply of freshwater. In many parts of the today’s world, desalination plays a vital role for sustaining human habitation besides the existing conventional water treatment technologies. Membrane based RO process has become a popular method to supply the fresh water from seawater and brackish water in different regions. RO (Figure 1) is a pressure driven process which under pressure reverses the flow direction of the solvent (in the opposite direction of osmosis process). Substantial efforts have been made by researchers on freshwater production (Sassi, 2012) and wastewater treatment (Stoller et al., 2016) using the RO. Rapid growth of membrane desalination processes enhanced the removal of ionic contaminants (Sassi and Mujtaba, 2013), pharmaceutical active compounds (Gur-Reznik et al., 2011) and other types of effluents from chemical, petrochemical, electrochemical, food, paper and tanning industries. Demineralised water can be supplied to several industries by treating the saline water using the RO process. However, there are limited studies on the production of demineralised water. Demineralised water is completely free (or almost) of dissolved minerals (Kremser et al. 2006) which has total dissolved solids (TDS) as low as 1 mg/l. Kremser et al. (2006) described operating experience on demineralized water plant.
In this work, RO based desalination process is considered using three stages described by (Sassi, 2012) as shown in Figure 1. The plant nominal operating and design parameters (of commercial Film Tec spiral wound RO membrane elements) are taken from Abbas (2005). Firstly, the model prediction is validated against those reported by Sassi and Mujtaba (2010). Secondly, an optimization problem incorporating a process model is formulated to optimize the design and operating parameters in order to minimize specific energy consumption and the results are compared with Sassi (2012). Since those models (Sassi, 2012) are validated for freshwater production, the model parameters such as (water and salt permeability coefficients) needs to be updated for demineralised water. A structure of the RO network is developed based on RO network (two-stage seawater pass and two-stage brackish water pass). Different parameters are updated for the model from the literature.
Design And Analysis of Pressure Disc Type Filter
Abstract:
Presently used Filters for Beverages making industries are very bulky in shape and gives low outlet discharge. Hence they are less efficient .Therefore there is a need to design compact, automated unit that produces completely clear liquor and which have large outlet discharge. This concept highlights the design of new filter which fulfill the requirements of beverages making industries for filtration. For making filtration more feasible, unit is to be design in which multiple disc comprising of blades is to be mounted on a shaft for filtration. Multiple discs will get patterned throughout the shaft and number of disc decides the capacity of filter. The special arrangement of Two cake discharge blades (scrapper remover) suspended from a frame mounted on the tank and serve to deflect and guide the cake to the discharge tube. On large diameter filters, the blades are of the swing type that float to maintain the cake to disc clearance and so allow for the wobble of the turning discs.
Design And Analysis of Pressure Disc Type Filter
Abstract:
Presently used Filters for Beverages making industries are very bulky in shape and gives low outlet discharge. Hence they are less efficient .Therefore there is a need to design compact, automated unit that produces completely clear liquor and which have large outlet discharge. This concept highlights the design of new filter which fulfill the requirements of beverages making industries for filtration. For making filtration more feasible, unit is to be design in which multiple disc comprising of blades is to be mounted on a shaft for filtration. Multiple discs will get patterned throughout the shaft and number of disc decides the capacity of filter. The special arrangement of Two cake discharge blades (scrapper remover) suspended from a frame mounted on the tank and serve to deflect and guide the cake to the discharge tube. On large diameter filters, the blades are of the swing type that float to maintain the cake to disc clearance and so allow for the wobble of the turning discs.
Design of Water Hammer Shock Absorber
Abstract:
In the piping system, water hammer or hydraulic shock is a major issue that engineers need to consider. Water hammer is a phenomenon that leads to shock waves in the fluid due to rapid closing and opening of the valve, which can affect pipes, valves and gauges in any water, gas, or oil applications due to the sudden transient event. It is there for every system that has a flow of fluid through pumping such as houses, hospitals, and influences major effectiveness in the power plant. It occurs when there is a pressure difference in the pipeline leading to a loud noise. Specifically, this project is aimed to design a pipeline system and develop solutions to reduce the water hammer using a shock absorber. The main idea of the design project is to design a water hammer system using a shock absorber in order to reduce the shock waves of the pipes.
Design of Water Hammer Shock Absorber
Abstract:
In the piping system, water hammer or hydraulic shock is a major issue that engineers need to consider. Water hammer is a phenomenon that leads to shock waves in the fluid due to rapid closing and opening of the valve, which can affect pipes, valves and gauges in any water, gas, or oil applications due to the sudden transient event. It is there for every system that has a flow of fluid through pumping such as houses, hospitals, and influences major effectiveness in the power plant. It occurs when there is a pressure difference in the pipeline leading to a loud noise. Specifically, this project is aimed to design a pipeline system and develop solutions to reduce the water hammer using a shock absorber. The main idea of the design project is to design a water hammer system using a shock absorber in order to reduce the shock waves of the pipes.
Chilled Water Plant Design Guide
Introduction:
Many large buildings, campuses, and other facilities have plants that make chilled water and distribute it to air handling units and other cooling equipment. The design operation and maintenance of these chilled water plants has a very large impact on building energy use and energy operating cost. Not only do chilled water plants use very significant amounts of electricity (as well as gas in some cases), they also significantly contribute to the peak load of buildings. The utility grid in California, and in many other areas of the country, experiences its maximum peak on hot summer days. During this peak event, chilled water plants are often running at maximum capacity. When temperatures are moderate, chilled water plants are shut down or operated in stand-by mode. This variation in the rate of energy use is a major contributor to the peaks and valleys in energy demand, which is one of the problems that must be addressed by utility grid managers. Most buildings and facilities that have chilled water plants have special utility rates where the cost of electricity depends on when it is used and the maximum rate of use. For instance, PG&E has five time charge periods: summer on-peak, summer mid-peak, summer off-peak, winter mid-peak and winter off-peak. The price of electricity is several times higher during the summer on-peak than it is during the off-peak periods. Not only does the cost of electricity vary, but most utility rates also have a monthly demand charge based on the maximum rate of electricity use for the billing period. Since chilled water plants operate more intensely during the summer peak period, efficiency gains and peak reductions can result in very large utility bill savings. In addition to new construction, the chilled water plants of many existing buildings are being replaced or overhauled. Older chilled water plants have equipment that uses ozone-damaging refrigerants. International treaties, in particular the Montreal Protocol, call for ozone damaging chemicals (in particular CFCs) to be phased out of production. As the availability of CFCs is reduced, the price will skyrocket, creating pressure for chilled water plants to be overhauled or replaced.
Chilled Water Plant Design Guide
Introduction:
Many large buildings, campuses, and other facilities have plants that make chilled water and distribute it to air handling units and other cooling equipment. The design operation and maintenance of these chilled water plants has a very large impact on building energy use and energy operating cost. Not only do chilled water plants use very significant amounts of electricity (as well as gas in some cases), they also significantly contribute to the peak load of buildings. The utility grid in California, and in many other areas of the country, experiences its maximum peak on hot summer days. During this peak event, chilled water plants are often running at maximum capacity. When temperatures are moderate, chilled water plants are shut down or operated in stand-by mode. This variation in the rate of energy use is a major contributor to the peaks and valleys in energy demand, which is one of the problems that must be addressed by utility grid managers. Most buildings and facilities that have chilled water plants have special utility rates where the cost of electricity depends on when it is used and the maximum rate of use. For instance, PG&E has five time charge periods: summer on-peak, summer mid-peak, summer off-peak, winter mid-peak and winter off-peak. The price of electricity is several times higher during the summer on-peak than it is during the off-peak periods. Not only does the cost of electricity vary, but most utility rates also have a monthly demand charge based on the maximum rate of electricity use for the billing period. Since chilled water plants operate more intensely during the summer peak period, efficiency gains and peak reductions can result in very large utility bill savings. In addition to new construction, the chilled water plants of many existing buildings are being replaced or overhauled. Older chilled water plants have equipment that uses ozone-damaging refrigerants. International treaties, in particular the Montreal Protocol, call for ozone damaging chemicals (in particular CFCs) to be phased out of production. As the availability of CFCs is reduced, the price will skyrocket, creating pressure for chilled water plants to be overhauled or replaced.
An Engineers Guide to Shaft Alignment, Vibration Analysis, Dynamic Balancing & Wear Debris Analysis
Introduction
The purpose of producing this handbook is to provide basic information and guidelines for the implementation of good shaft alignment, vibration analysis and dynamic balancing practice for standard rotating machines systems.
Laser alignment, dynamic balancing and condition monitoring are essential components of a viable maintenance strategy for rotating machines. In isolation each strategy helps to reduce unexpected machine failure but taken together they form the hub of a proactive maintenance strategy that will not only identify incipient problems but will extend machine operating life considerably.
In each section of this handbook we have used one or two examples of the available methods for measuring the required parameters. We do not suggest that the methods illustrated are the only ones available. For anyone wishing to pursue further the subjects covered here a bibliography of some of the available literature is to be found at the end of this handbook.
An Engineers Guide to Shaft Alignment, Vibration Analysis, Dynamic Balancing & Wear Debris Analysis
Introduction
The purpose of producing this handbook is to provide basic information and guidelines for the implementation of good shaft alignment, vibration analysis and dynamic balancing practice for standard rotating machines systems.
Laser alignment, dynamic balancing and condition monitoring are essential components of a viable maintenance strategy for rotating machines. In isolation each strategy helps to reduce unexpected machine failure but taken together they form the hub of a proactive maintenance strategy that will not only identify incipient problems but will extend machine operating life considerably.
In each section of this handbook we have used one or two examples of the available methods for measuring the required parameters. We do not suggest that the methods illustrated are the only ones available. For anyone wishing to pursue further the subjects covered here a bibliography of some of the available literature is to be found at the end of this handbook.
Reviews