Laboratory & Water Quality
Improving Water Utility’s Performance In Lahan (NWSC Branch)
Views : 4
Improving Water Utility’s Performance In Lahan (NWSC Branch)
Source: https://www.anglianwater.co.uk
Prepared By: Shirish Rajbhandari, Andy Smith, Dharma Ratna Chitrakar
Usually dispatched in 2 to 3 days
Usually dispatched in 2 to 3 days
Category:
Laboratory & Water Quality
Only logged in customers who have purchased this product may leave a review.
Related books
Effects of Heavy Metals on Cell Density, Size, Specific Growth Rate and Chlorophyll a of Tetraselmis Tetrathele Under Controlled Laboratory Conditions
Abstract
The effects of the varying levels of mercury (Hg) and cadmium (Cd) (0, 0.1, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0 and 5.0 mg L⁻¹) to the cellular density of the green microalgae Tetraselmis tetrathele were evaluated every 24 h for 120 h. Specific growth rate, cell sizes and chlorophyll a were also monitored in the 5.0 mg L⁻¹ Hg and Cd and were compared to the unexposed at 0, 12, 24, 36, 48 and 120h. Results showed that the algal density of T. tetrathele exposed to various levels of Hg were similar with the control up to 48 h. Variations on different concentrations at different times were observed but the results suggest that T. tetrathele was not affected by Hg even at concentrations up to 5.0 mg L⁻¹ for 48 h but started to show toxicity from 3.0 to 5.0 mg L⁻¹ after 72 h and longer. Cd on the other hand also showed toxicity at 3.0, 4.0 and 5.0 mg L⁻¹ beyond 24 h exposure. The specific growth rate of T. tetrathele exposed to both 5.0 mg L⁻¹ Hg and Cd was statistically similar with those of the unexposed from 0 to 12 h and negative growth rates then followed up to 36 h. The chlorophyll a was significantly lower in the metal -exposed algae than did those unexposed. Chlorophyll a also decreased in T. tetrathele exposed to both heavy metals but algal cell sizes were not affected with the presence of Hg or Cd in the culture system.
Effects of Heavy Metals on Cell Density, Size, Specific Growth Rate and Chlorophyll a of Tetraselmis Tetrathele Under Controlled Laboratory Conditions
Abstract
The effects of the varying levels of mercury (Hg) and cadmium (Cd) (0, 0.1, 0.3, 0.5, 1.0, 2.0, 3.0, 4.0 and 5.0 mg L⁻¹) to the cellular density of the green microalgae Tetraselmis tetrathele were evaluated every 24 h for 120 h. Specific growth rate, cell sizes and chlorophyll a were also monitored in the 5.0 mg L⁻¹ Hg and Cd and were compared to the unexposed at 0, 12, 24, 36, 48 and 120h. Results showed that the algal density of T. tetrathele exposed to various levels of Hg were similar with the control up to 48 h. Variations on different concentrations at different times were observed but the results suggest that T. tetrathele was not affected by Hg even at concentrations up to 5.0 mg L⁻¹ for 48 h but started to show toxicity from 3.0 to 5.0 mg L⁻¹ after 72 h and longer. Cd on the other hand also showed toxicity at 3.0, 4.0 and 5.0 mg L⁻¹ beyond 24 h exposure. The specific growth rate of T. tetrathele exposed to both 5.0 mg L⁻¹ Hg and Cd was statistically similar with those of the unexposed from 0 to 12 h and negative growth rates then followed up to 36 h. The chlorophyll a was significantly lower in the metal -exposed algae than did those unexposed. Chlorophyll a also decreased in T. tetrathele exposed to both heavy metals but algal cell sizes were not affected with the presence of Hg or Cd in the culture system.
Water Treatment and Pathogen Control
This document is part of a series of expert reviews on different aspects of microbial water quality and health, developed by the World Health Organization (WHO) to inform development of guidelines for drinking-water quality, and to help countries and suppliers to develop and implement effective water safety plans. Contamination of drinking-water by microbial pathogens can cause disease outbreaks and contribute to background rates of disease. There are many treatment options for eliminating pathogens from drinking-water. Finding the right solution for a particular supply involves choosing from a range of processes. This document is a critical review of some of the literature on removal and inactivation of pathogenic microbes in water. The aim is to provide water quality specialists and design engineers with guidance on selecting appropriate treatment processes, to ensure the production of high quality drinking-water. Specifically, the document provides information on choosing appropriate treatment in relation to raw water quality, estimating pathogen concentrations in drinking-water, assessing the ability of treatment processes to achieve health-based water safety targets and identifying control measures in process operation.
Water Treatment and Pathogen Control
This document is part of a series of expert reviews on different aspects of microbial water quality and health, developed by the World Health Organization (WHO) to inform development of guidelines for drinking-water quality, and to help countries and suppliers to develop and implement effective water safety plans. Contamination of drinking-water by microbial pathogens can cause disease outbreaks and contribute to background rates of disease. There are many treatment options for eliminating pathogens from drinking-water. Finding the right solution for a particular supply involves choosing from a range of processes. This document is a critical review of some of the literature on removal and inactivation of pathogenic microbes in water. The aim is to provide water quality specialists and design engineers with guidance on selecting appropriate treatment processes, to ensure the production of high quality drinking-water. Specifically, the document provides information on choosing appropriate treatment in relation to raw water quality, estimating pathogen concentrations in drinking-water, assessing the ability of treatment processes to achieve health-based water safety targets and identifying control measures in process operation.
Clearing the Waters A focus on water quality solutions
Reproduction
This publication may be reproduced in whole or in part and in any form for educational or nonprofit purposes without special permission from the copyright holders, provided acknowledgement of the source is made. UNEP would appreciate receiving a copy of any publication that uses this publication as a source. No use of this publication may be made for resale or for any other commercial purpose whatsoever without prior permission in writing from the United Nations Environment Programme.
Clearing the Waters A focus on water quality solutions
Reproduction
This publication may be reproduced in whole or in part and in any form for educational or nonprofit purposes without special permission from the copyright holders, provided acknowledgement of the source is made. UNEP would appreciate receiving a copy of any publication that uses this publication as a source. No use of this publication may be made for resale or for any other commercial purpose whatsoever without prior permission in writing from the United Nations Environment Programme.
Effect of the Quality of Water Used for Dialysis on the Efficacy of Hemodialysis
Abstract
The quality of the water used for dialysis has been suggested as a factor causing inflammation in patients on hemodialysis (HD). We therefore conducted this study to identify the effect of quality of the water on nutritional state, inflammation and need for human recombinant erythropoietin (EPO) in patients undergoing HD at Agadir, Morocco. This prospective study included patients on HD for at least one year. The water treatment was done according to the standard protocol, which was followed by additional enhancement of ultrafiltration using an additional polysulfone filter (diasafe, Fresenius, Bad Homburg, Germany) before the dialyser. Water was monitored regularly during the study period to ensure acceptable levels of bacterial count as well as endotoxin levels. Various parameters including dry weight, systolic and diastolic blood pressure (PA) before and after an HD session, need for human recombinant EPO, levels of hemoglobin (Hb), albumin, ferritin, C-reactive protein (CRP), and the dose of dialysis delivered (Kt/V) were measured first at the beginning of the study and thereafter, in the third, sixth and 12 th months of the study. The study involved 47 patients, and after 12 months of the study, an improvement in median dry weight (1.2 kg, P = 0017) and a simultaneous median reduction of 20.7 IU/kg/week of EPO, with an in-crease of the median level of Hb, was noted. The results of our study suggest that by improving the biocompatibility of HD with the use of good quality water, patients acquire a better nutritional, inflammatory and hematologic status.
Effect of the Quality of Water Used for Dialysis on the Efficacy of Hemodialysis
Abstract
The quality of the water used for dialysis has been suggested as a factor causing inflammation in patients on hemodialysis (HD). We therefore conducted this study to identify the effect of quality of the water on nutritional state, inflammation and need for human recombinant erythropoietin (EPO) in patients undergoing HD at Agadir, Morocco. This prospective study included patients on HD for at least one year. The water treatment was done according to the standard protocol, which was followed by additional enhancement of ultrafiltration using an additional polysulfone filter (diasafe, Fresenius, Bad Homburg, Germany) before the dialyser. Water was monitored regularly during the study period to ensure acceptable levels of bacterial count as well as endotoxin levels. Various parameters including dry weight, systolic and diastolic blood pressure (PA) before and after an HD session, need for human recombinant EPO, levels of hemoglobin (Hb), albumin, ferritin, C-reactive protein (CRP), and the dose of dialysis delivered (Kt/V) were measured first at the beginning of the study and thereafter, in the third, sixth and 12 th months of the study. The study involved 47 patients, and after 12 months of the study, an improvement in median dry weight (1.2 kg, P = 0017) and a simultaneous median reduction of 20.7 IU/kg/week of EPO, with an in-crease of the median level of Hb, was noted. The results of our study suggest that by improving the biocompatibility of HD with the use of good quality water, patients acquire a better nutritional, inflammatory and hematologic status.
Developing Quality Control Handbooks for Water and Wastewater Treatment
Introduction
This section provides a step by step discussion regarding the development of a Quality Control Handbook for a water or wastewater treatment plant. A workshop format has been chosen for the development of the handbook in order to channel the multiple knowledge inputs needed for it. For a proper. The workshop format targets participants coming from water or wastewater treatment facilities. These participants are expected to be knowledgeable of the operational activities of the plant and able to share their actual experiences. The successful implementation of this handbook depends on the creation of a setting in which the employees themselves act as both teachers and students. Active participation is a key success factor, and practical demonstrations are necessary to supplement the theoretical aspects. The workshop format can be easily replicated and as such, helps facilitate the development of operating manuals in other water treatment facilities or water companies. Once completed, these manuals may be used to define the required skills of the operating personnel and may also be used for actual on-the-job training. The handbook is to be finalized after successful completion of four group sessions.
Developing Quality Control Handbooks for Water and Wastewater Treatment
Introduction
This section provides a step by step discussion regarding the development of a Quality Control Handbook for a water or wastewater treatment plant. A workshop format has been chosen for the development of the handbook in order to channel the multiple knowledge inputs needed for it. For a proper. The workshop format targets participants coming from water or wastewater treatment facilities. These participants are expected to be knowledgeable of the operational activities of the plant and able to share their actual experiences. The successful implementation of this handbook depends on the creation of a setting in which the employees themselves act as both teachers and students. Active participation is a key success factor, and practical demonstrations are necessary to supplement the theoretical aspects. The workshop format can be easily replicated and as such, helps facilitate the development of operating manuals in other water treatment facilities or water companies. Once completed, these manuals may be used to define the required skills of the operating personnel and may also be used for actual on-the-job training. The handbook is to be finalized after successful completion of four group sessions.
Reviews
There are no reviews yet.